- Experimental and numerical study on an adjustable steel façade connector for hybrid timber-concrete structuresAlice Le Berder, Tran-Van Han, Tuan-Anh Nguyen, and 2 more authorsStructures, Jun 2026
This study investigates the structural performance of a novel steel connector featuring a serrated interface, developed for attaching timber frame façades to reinforced concrete slabs in hybrid construction. Four full-scale specimens were tested under two representative loading scenarios: combined wind suction and gravity load (Configuration 1), and pure gravity load (Configuration 2). Configuration 1 exhibited a tension–shear response governed by brittle fracture of connection bolts, whereas Configuration 2 showed a ductile plate-dominated behavior characterized by progressive counterbore tear-out. These two configurations illustrate distinct load-transfer and failure mechanisms expected under different façade loading conditions. Finite element analyses in LS-DYNA accurately reproduced the load–displacement behavior and captured the transition from bolt-governed fracture to plate-dominated tearing. A semi–analytical component-based model, calibrated against experimental and numerical results, provided consistent predictions of stiffness and resistance. The results further indicate that, under the considered serviceability and ultimate limit state load cases, the connector remains within the quasi-elastic range, highlighting its practical suitability for façade applications. The findings also emphasize the importance of considering both combined and gravity-dominated loading in façade connection design.
@article{berder2026experimental88, title = {Experimental and numerical study on an adjustable steel façade connector for hybrid timber-concrete structures}, author = {Le Berder, Alice and Han, Tran-Van and Nguyen, Tuan-Anh and Lepourry-Nicollet, Clemence and Somja, Hugues}, journal = {Structures}, volume = {88}, pages = {111986}, year = {2026}, month = jun, doi = {10.1016/j.istruc.2026.111986} } - Experimental and analytical studies on the compressive behaviors of a 3D-printed sand mold-cast S-CN connector in modular steel buildingsTran-Van Han, Jeong MoonSook, YongNam Kim, and 3 more authorsAlexandria Engineering Journal, Jan 2026
Steel modular construction offers advantages in speed, cost, and sustainability, but its adoption is constrained by connection efficiency. This study introduces the Samsung Connection Node (S-CN), a novel cast-steel connector fabricated using 3D-printed sand molds. Full-scale tests on roof nodes, floor nodes, the connector, and a beam–column assembly under axial compression were conducted, supported by finite element (FE) and analytical studies. Roof nodes carried 10% higher loads than floor nodes, while connector strength was governed by tie plate deformation and local buckling. Beam restraint improved load utilization, producing higher uniformity of strain. Code-based predictions (AISC 360-16 EN 1993-1-1) provided conservative agreement with experiments and FE. A mechanics-based model clarified that rim bearing controls global capacity, while yield-line mechanisms explain local deformation. Parametric studies highlighted the strong influence of node thickness and adverse effects of large openings or excessive column height. Supplementary FE analyses under combined axial–moment loading indicated a stable numerical response of the connector and suggested robustness under service-level eccentricities. A nonlinear pushover analysis of a corner subassembly suggested a ductility ratio of 7.5 with drift ratios below the ASCE 7 and Eurocode 8 near-collapse limits in the numerical model; these seismic-related findings are preliminary and require future experimental validation.
@article{han2026experimental134, title = {Experimental and analytical studies on the compressive behaviors of a 3D-printed sand mold-cast S-CN connector in modular steel buildings}, author = {Han, Tran-Van and MoonSook, Jeong and Kim, YongNam and Sanh, Tra Ngoc and Cuong, Nguyen Huu and Lee, Kihak}, journal = {Alexandria Engineering Journal}, volume = {134}, pages = {473--493}, year = {2026}, month = jan, doi = {10.1016/j.aej.2025.12.013}, }
2025
- Performance assessment of a novel connector for timber frame facades on concrete slabsTran-Van Han, Alice Le Berder, Tuan-Anh Nguyen, and 2 more authorsJournal of Building Engineering, Nov 2025
This study examines the structural performance of a U-profile fastening system designed to connect timber frame façades (TFFs) to concrete slabs in hybrid timber–concrete construction. The system consists of U-shaped steel profiles with flange cutouts, partially embedded in concrete to facilitate early-stage façade installation. Fifteen full-scale specimens, varying in embedment depth, cutout geometry, and concrete compressive strength, were tested under simulated wind loads representing suction conditions. Concrete cone breakout was identified as the predominant failure mode. Experimental results indicated that embedment depth and concrete strength were the main factors governing anchorage resistance. In contrast, variations in cutout geometry and localized reinforcement had minimal influence. Finite element simulations captured the overall structural behavior and failure mechanisms with acceptable accuracy, showing a maximum deviation of 7% in peak load relative to experimental results. An analytical model, based on the Concrete Capacity method and existing design standards, was developed to estimate anchorage capacity and showed consistent agreement across the tested configurations. The findings contribute to the structural design of timber–concrete façade connections incorporating embedded U-profile connectors.
@article{han2025performance114, title = {Performance assessment of a novel connector for timber frame facades on concrete slabs}, author = {Han, Tran-Van and Le Berder, Alice and Nguyen, Tuan-Anh and Lepourry-Nicollet, Clemence and Somja, Hugues}, journal = {Journal of Building Engineering}, volume = {114}, pages = {114397}, year = {2025}, month = nov, doi = {10.1016/j.jobe.2025.114397}, } - Experimental and numerical study of the acoustic performance of a novel composite core thermal breakTran-Van Han, Gayoon Lee, Yun-Seong Shin, and 2 more authorsCase Studies in Construction Materials, Jul 2025
This study assesses the acoustic performance of a novel thermal break system with composite cores through both experimental testing and Finite element (FE) analysis. The research explores the effects of varying the thicknesses of key materials, including Expanded Polystyrene (EPS), Cellulose Fiber Reinforced Cement (CRC) boards, and Melamine foam, on sound insulation while maintaining a constant overall thickness of the thermal break. Results show that reducing EPS thickness and increasing CRC or Melamine foam thickness by 12 mm, along with strategic layering of Melamine with CRC boards, enhances sound insulation by 2–5 decibels (dB). The configuration with the thickest Melamine foam layer achieved the highest sound insulation improvement, ranging from 2 to 6 dB over other configurations. Additionally, FE vibro-acoustic analysis proved to be a reliable predictor of acoustic performance, closely aligning with experimental data. A parametric study further revealed a nearly linear correlation between EPS layer thickness and sound insulation efficacy. These findings underscore the crucial role of material selection and strategic layering in designing thermal breaks that effectively balance sound and thermal insulation, contributing to improved environmental quality and occupant comfort in buildings
@article{han2025experimental22, title = {Experimental and numerical study of the acoustic performance of a novel composite core thermal break}, author = {Han, Tran-Van and Lee, Gayoon and Shin, Yun-Seong and Woo, Sungwoo and Lee, Kihak}, journal = {Case Studies in Construction Materials}, volume = {22}, pages = {e04543}, year = {2025}, month = jul, doi = {10.1016/j.cscm.2025.e04543}, } - Vibro-acoustic testing on impact sound performance of novel floating floor systems with polyurethane cushionsTran-Van Han, Gayoon Lee, Sang Whan Han, and 3 more authorsJournal of Building Engineering, Apr 2025
Impact sound transmission in concrete slabs is a persistent challenge in building acoustics, particularly in residential and commercial environments. This study introduces a novel floating floor design utilizing polyurethane cushions of various 3D shapes and sizes to mitigate impact noise. The aim is to improve acoustic performance across a wide frequency spectrum while maintaining flexibility and practicality in installation. Two floating floor configurations — fully-filled and half-filled systems — were experimentally tested on twenty-two specimens under controlled laboratory conditions. Fully-filled systems achieved significant impact sound reductions of up to 6.8 dB, delivering consistent performance in mid to high frequencies and low frequencies when appropriately configured. In contrast, half-filled systems were effective at controlling low-frequency noise but demonstrated limitations at higher frequencies due to resonance sensitivity and variability in configurations. Parametric studies revealed that optimizing polyurethane cushion properties, such as elastic modulus and height, enhanced overall impact sound performance. Additionally, incorporating lightweight concrete layers significantly improved low-frequency insulation. Fully-filled systems consistently outperformed conventional methods, delivering comprehensive and reliable sound insulation. However, half-filled systems require further refinement for broader acoustic applications. This research highlights the critical role of cushion material properties, structural configurations, and multi-layer designs in effective impact sound control, providing a solid foundation for next-generation floating floor systems tailored to advanced acoustic insulation needs.
@article{han2025vibroacoustic100, title = {Vibro-acoustic testing on impact sound performance of novel floating floor systems with polyurethane cushions}, author = {Han, Tran-Van and Lee, Gayoon and Han, Sang Whan and An, Tae-Sang and Jeong, Chan-Yu and Lee, Kihak}, journal = {Journal of Building Engineering}, volume = {100}, pages = {111720}, year = {2025}, month = apr, doi = {10.1016/j.jobe.2024.111720}, } - Experimental and numerical evaluation of the structural performance of novel S-CN connections in modular constructionTran-Van Han, MoonSook Jeong, YongNam Kim, and 3 more authorsStructures, Jan 2025
The novel S-CN (Samsung Connection Nodes) connection system, featuring nodes crafted from 3D-printed sand molds and integrated with vertical and horizontal components paired with rectangular hollow section (RHS) members, provides an effective method for connecting modules in steel modular buildings. This study employs experimental and numerical methods to assess the axial compression and tensile capacities of vertical connections, as well as the shear capacities of horizontal connections. Results show that the vertical connection’s axial capacity is significantly influenced by the thickness of the roof node’s top plate. While the reduction in area due to the roof node’s openings affects compression performance, it has minimal impact on tensile performance. Similarly, the shear capacities of horizontal connections depend on the capacities of their shear pins. The parametric study reveals that increasing the thickness of the roof node’s top plate leads to a linear increase in both the ultimate tensile and compression loads of the vertical connections. Additionally, increasing the diameter of the shear pins results in a modest increase in the ultimate shear load of the horizontal connections. **BibTeX**:
@articlehan2025experimental, title=Experimental and numerical evaluation of the structural performance of novel S-CN connections in modular construction, author=Han, Tran-Van and Jeong, MoonSook and Kim, YongNam and Lee, Dongkyu and Cuong, Nguyen Huu and Lee, Kihak, journal=Structures, volume=71, pages=107930, year=2025, publisher=Elsevier@article{han2025experimental71, title = {Experimental and numerical evaluation of the structural performance of novel S-CN connections in modular construction}, author = {Han, Tran-Van and Jeong, MoonSook and Kim, YongNam and Lee, Dongkyu and Cuong, Nguyen Huu and Lee, Kihak}, journal = {Structures}, volume = {71}, pages = {107930}, year = {2025}, month = jan, doi = {10.1016/j.istruc.2024.107930}, }
2024
- Biaxial shaking table testing of large-scale novel wireway vibration attenuation systemsTran-Van Han, Sung Chan Kim, Jiuk Shin, and 2 more authorsJournal of Building Engineering, Nov 2024
This research examines the seismic performance of large-scale pulley wireway systems subjected to four consecutive earthquakes using biaxial shaking table tests. A comparative analysis was conducted between novel lighting systems and a conventional raceway lighting system, each 20.50 m in length. Four specimens were tested: three pulley wireway systems and one conventional raceway lighting system, with varying suspended heights, support configurations, and cable pre-tension forces. The shaking table tests used time–history acceleration data to simulate artificial earthquakes per the ICC-ES AC156 standard. The results show that the novel lighting system exhibited superior earthquake performance and stability, outperforming the conventional system. Raising the suspension height increased seismic response and energy for the novel systems. Increasing cable tension improved stability under low seismic intensity but significantly increased seismic energy and response at high intensity. The absence of main hangers, combined with increased cable tension, reduced relative displacement but introduced instability at the ends and increased earthquake energy. These findings highlight the need to optimize suspension height, cable tension, and support configurations to enhance system resilience during earthquakes.
@article{han2024biaxial97, title = {Biaxial shaking table testing of large-scale novel wireway vibration attenuation systems}, author = {Han, Tran-Van and Kim, Sung Chan and Shin, Jiuk and Cuong, Nguyen Huu and Lee, Kihak}, journal = {Journal of Building Engineering}, volume = {97}, pages = {110792}, year = {2024}, month = nov, doi = {10.1016/j.jobe.2024.110792}, } - Structural test and FEM analysis of a thermal bridge connection employing the UHPC system for concrete cladding wallNguyen Huu Cuong, Hyoseo An, Tran-Van Han, and 3 more authorsResults in Engineering, Jun 2024
The paper describes the technical design used to develop a structure model that improved thermal insulation properties and structural performance. This study experimentally and analytically investigated the shear capacity of a precast ultra-high performance concrete (UHPC) rib with a concrete cladding wall through the shear keys connection. The structural performance was examined by conducting tests on five specimens under conditions of static loading of the UHPC rib with and without shear keys. The test results revealed that the structural load capacity is significantly affected by changes to the dimensions and design of the shear key, as well as the eccentricity distance in these specimens, the load capacity was approximately 3 to 4 times higher compared to conventional solutions. Numerical models were built to simultaneously predict the shear capacity of structures with varying loading positions and crack failure. These results demonstrated that the proposed modeling may be effectively used to verify the experimental results. Several important input parameters, a constitutive model, and a bar-concrete interface in the LS-DYNA program are suggested.
@article{cuong2024structural22, title = {Structural test and FEM analysis of a thermal bridge connection employing the UHPC system for concrete cladding wall}, author = {Cuong, Nguyen Huu and An, Hyoseo and Han, Tran-Van and An, Sanghee and Shin, Jiuk and Lee, Kihak}, journal = {Results in Engineering}, volume = {22}, pages = {102191}, year = {2024}, month = jun, doi = {10.1016/j.rineng.2024.102191} } - Structural test and analyses of UHPC horizontal connection with shear keys for slab-external PC wallNguyen Huu Cuong, Hyoseo An, Han V. Tran, and 2 more authorsConstruction and Building Materials, Mar 2024
In residential buildings, the connection between the wall and the slab is the most important area for the design to prevent structural failure and heat loss. The research objective is to evaluate the load capacity of connecting shear keys to an existing slab and panel concrete (PC) wall structure, as well as to develop a design for this connection under direct shear and bending. The experimental program included four test specimens, two of which had one shear key and two shear keys for the others for each loading condition. The test results demonstrate that the structural bearing capacity of bending and shear are significantly improved by changes to the dimensions of the slab, the design of the shear key, and the number of ribs, with the ultimate load increased by 54.45% and 56.85%, respectively. In addition, a finite element (FE) model was used to numerically simulate the behavior of all specimens. The crack and load–displacement curves of the numerical simulations were validated against experimental results using the LS-DYNA program, and good agreement was observed, demonstrating the effectiveness of the numerical model for simulating the behavior of the system components. Several critical input parameters, a constitutive model, and a bar–concrete interface are recommended. The experiments and simulations highlight the effectiveness of various technical solutions for boosting the load capacity of the structure.
@article{cuong2024structural419, title = {Structural test and analyses of UHPC horizontal connection with shear keys for slab-external PC wall}, author = {Cuong, Nguyen Huu and An, Hyoseo and Tran, Han V. and An, Sanghee and Lee, Kihak}, journal = {Construction and Building Materials}, volume = {419}, pages = {135410}, year = {2024}, month = mar, doi = {10.1016/j.conbuildmat.2024.135410}, } - Tri-axial shaking table testing of lighting support systems with pulley friction dampers and integrated dummy massesTran-Van Han, Sung Chan Kim, Jiuk Shin, and 2 more authorsResults in Engineering, Mar 2024
Investigating pulley wireway systems equipped with friction dampers as alternatives to traditional exposed raceway light fixtures, this study adheres to the ICC-ES AC156 standard and evaluates the impact of system mass and connector types on seismic behavior using shaking table tests. The key findings indicate that an increased system mass variably affects the fundamental frequency of the system, depending on the type of connectors. In terms of earthquake performance, direct connectors outperformed pole connectors in the original system configuration, and the addition of dummy masses significantly reduced seismic energy while stabilizing acceleration responses in pole connector systems. Moreover, the study underscores the critical importance of minimizing pole length in systems using pole connectors and adopting a lower mounting height in systems with direct connectors to improve seismic performance.
@article{han2024triaxial21, title = {Tri-axial shaking table testing of lighting support systems with pulley friction dampers and integrated dummy masses}, author = {Han, Tran-Van and Kim, Sung Chan and Shin, Jiuk and Cuong, Nguyen Huu and Lee, Kihak}, journal = {Results in Engineering}, volume = {21}, pages = {101706}, year = {2024}, month = mar, doi = {10.1016/j.rineng.2023.101706} } - Numerical study on compressive behavior of a 3D-printed sand mold-cast S-CN connectorTran-Van Han, Jeong MoonSook, YongNam Kim, and 3 more authorsJournal of Constructional Steel Research, Feb 2024
This paper presents a novel approach for steel modular structures, incorporating the S-CN connector – a hybrid tie rod and connector connection method – along with rectangular hollow section (RHS) steel members. The study numerically investigates the mechanical behavior of S-CN connectors and their application in beam–column connections under compressive loading. The compressive load-bearing capacity of the proposed connection is determined following AISC 360-16 guidelines, predicted through a finite element analysis approach and validated by experimental data. Parametric analysis reveals the impact of local buckling in modular nodes on the connector’s load-bearing capacity. The results demonstrate that tie plate thickness has a minimal effect, while reducing the modular node thickness leads to a linear decrease in load capacities. Furthermore, the failure mode of the beam–column connection depends on the compressive capacities of both the RHS column and the S-CN connector.
@article{han2024numerical213, title = {Numerical study on compressive behavior of a 3D-printed sand mold-cast S-CN connector}, author = {Han, Tran-Van and MoonSook, Jeong and Kim, YongNam and Lee, Dongkyu and Luat, Nguyen-Vu and Lee, Kihak}, journal = {Journal of Constructional Steel Research}, volume = {213}, pages = {108336}, year = {2024}, month = feb, doi = {10.1016/j.jcsr.2023.108336}, }
2022
- Shaking table testing of an innovative wireway vibration attenuation systemHan V. Tran, Sung Chan Kim, Jiuk Shin, and 1 more authorJournal of Constructional Steel Research, Oct 2022
The seismic performance of lighting systems is rarely reported in the literature, although previous studies indicate that they could be vulnerable during an earthquake. This study investigated the effect of various connectors on the seismic performance of an innovative wireway vibration attenuation system for raceway light fixtures using shaking table tests based on the ICC-ES AC156 standard. The floor spectrum was created, and its compatible floor motion time history was employed as the input motion. Four typical prototypes were prepared with connectors suitable for mounting on a variety of structural components, including ceiling, H-beam frame, wall, and beam-column. The test results demonstrated that the specimens with the direct connectors (wall and H-beam frame) had excellent seismic performance, 1.4–2.0 times higher than those with the pole connectors (ceiling and beam-column). Therefore, the direct connectors are proposed for this innovative system to decrease the risk of system failure during an earthquake.
@article{tran2022shaking197, title = {Shaking table testing of an innovative wireway vibration attenuation system}, author = {Tran, Han V. and Kim, Sung Chan and Shin, Jiuk and Lee, Kihak}, journal = {Journal of Constructional Steel Research}, volume = {197}, pages = {107477}, year = {2022}, month = oct, doi = {10.1016/j.jcsr.2022.107477}, } - Experimental study of a novel lighting support system reinforced with a pulley friction damperHan V. Tran, Sung Chan Kim, Jiuk Shin, and 1 more authorJournal of Building Engineering, Jul 2022
The pulley wireway system, a novel lighting support system reinforced with a pulley friction damper, can become an attractive earthquake-resistant alternative to conventional lighting systems in buildings. The goal of this research was to conduct a thorough evaluation of the seismic energy dissipation capacities of both a novel and an existing lighting support system under artificial earthquakes of varying magnitudes, generated using the ICC-ES AC156 standard. This was achieved by conducting tri-axial shaking table tests on two specimens suspended from the same height and using the same connector type. The experimental results demonstrated that the newly developed lighting support system with the damper was effective in reducing seismic energy and peak oscillation. The effectiveness of the damper was directly proportional to the magnitude of the earthquake, resulting in excellent adaptability of this innovative system to a wide range of earthquake events.
@article{tran2022experimental52, title = {Experimental study of a novel lighting support system reinforced with a pulley friction damper}, author = {Tran, Han V. and Kim, Sung Chan and Shin, Jiuk and Lee, Kihak}, journal = {Journal of Building Engineering}, volume = {52}, pages = {104385}, year = {2022}, month = jul, doi = {10.1016/j.jobe.2022.104385}, }
Conference papers
2025
- fibExperimental and analytical study on anchorage performance of a new fastening system for wood-frame façadeAlice Le Berder, Tran-Van Han, Tuan-Anh Nguyen, and 2 more authorsIn Proceedings of the fib Symposium 2025, 2025
@inproceedings{leberder2025fib, title = {Experimental and analytical study on anchorage performance of a new fastening system for wood-frame façade}, author = {Le Berder, Alice and Han, Tran-Van and Nguyen, Tuan-Anh and Lepourry-Nicollet, Clémence and Somja, Hugues}, booktitle = {Proceedings of the fib Symposium 2025}, address = {Antibes, France}, pages = {2062--2073}, year = {2025}, }
2024
- ICSVAssessment of sound insulation for innovative ultra-high-performance concrete core thermal breaksTran-Van Han, Gayoon Lee, Nguyen Huu Cuong, and 1 more authorIn Proceedings of the 30th International Congress on Sound and Vibration (ICSV30), 2024
This study examines the acoustic performance of a novel thermal break featuring Ultra-High-Performance Concrete (UHPC) cores and thermal insulation layers, aimed at reducing heat loss at building wall junctions. By adjusting the thicknesses of expanded polystyrene (EPS), cellulose fiber reinforced cement board (CRC), and Melamine foam, it identifies optimal configurations for enhanced sound insulation. Key findings from the tests suggest that reducing the thickness of EPS while incorporating thicker CRC layers, and increasing the thickness of Melamine foam, significantly improves the sound insulation performance. Additionally, a numerical analysis was conducted and validated by experimental data, emphasizing the critical impact of material selection on the sound insulation efficacy of the novel thermal break.
@inproceedings{han2024icsv, title = {Assessment of sound insulation for innovative ultra-high-performance concrete core thermal breaks}, author = {Han, Tran-Van and Lee, Gayoon and Cuong, Nguyen Huu and Lee, Kihak}, booktitle = {Proceedings of the 30th International Congress on Sound and Vibration (ICSV30)}, address = {Amsterdam, Netherlands}, year = {2024}, }
2023
- ICSVAcoustic performance of a novel floating floor with rubber cushionsTran-Van Han, Gayoon Lee, Kihak Lee, and 3 more authorsIn Proceedings of the 29th International Congress on Sound and Vibration (ICSV29), 2023
The most problematic noise in apartment buildings is structure-borne sound, which is created when an impact causes the floor to vibrate and radiate sound. Until now, several studies focus on developing multiple layers of resilient materials are used to construct floating floors in order to absorb impact and minimize structure-borne noise. This study proposes a novel floating floor with rubber cushions for reducing floor impact noises. Experiments using a mockup of the proposed floating floors subjected to heavy impact loading were conducted on floor configurations with various rubber cushion shapes. Furthermore, a numerical analysis was carried out and verified by experimental data. According to the experimental and analytical results, increasing the height of the rubber cushions and adding a layer of lightweight concrete lowers the heavy-weight floor impact sound and improve acoustic performance for conventional concrete floor systems.
@inproceedings{han2023icsv, title = {Acoustic performance of a novel floating floor with rubber cushions}, author = {Han, Tran-Van and Lee, Gayoon and Lee, Kihak and Han, Sang Whan and An, Tae-Sang and Jeong, Chan-Yu}, booktitle = {Proceedings of the 29th International Congress on Sound and Vibration (ICSV29)}, address = {Prague, Czech Republic}, year = {2023}, }